Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
J Orthop Res ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38564320

RESUMEN

This study aimed to compare three-dimensional (3D) proximal femoral and acetabular surface models generated from 3.0T magnetic resonance imaging (MRI) to the clinical gold standard of computed tomography (CT). Ten intact fresh-frozen cadaveric hips underwent CT and 3.0T MRI scans. The CT- and MRI-based segmented models were superimposed using a validated 3D-3D registration volume-merge method to compare them. The least surface-to-surface distance between the models was calculated by a point-to-surface calculation algorithm using a custom-written program. The variables of interest were the signed and absolute surface-to-surface distance between the paired bone models. One-sample t-tests were performed using a signed and absolute test value of 0.16 mm and 0.37 mm, respectively, based on a previous study that validated 1.5T MRI bone models by comparison with CT bone models. For the femur, the average signed and absolute surface-to-surface distance was 0.18 ± 0.09 mm and 0.30 ± 0.06 mm, respectively. There was no difference in the signed surface-to-surface distance and the 0.16 mm test value (t = 0.650, p = 0.532). However, the absolute surface-to-surface difference was less than the 0.37 mm test value (t = -4.025, p = 0.003). For the acetabulum, the average signed and absolute surface-to-surface distance was -0.06 ± 0.06 mm and 0.26 ± 0.04 mm, respectively. The signed (t = -12.569, p < 0.001) and absolute (t = -8.688, p < 0.001) surface-to-surface difference were less than the 0.16 mm and 0.37 mm test values, respectively. Our data shows that 3.0T MRI bone models are more similar to CT bone models than previously validated 1.5T MRI bone models. This is likely due to the higher resolution of the 3T data.

2.
Eur Spine J ; 33(4): 1398-1406, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451373

RESUMEN

PURPOSE: The following study aimed to determine the existence of blood biomarkers in symptomatic patients with or without lumbar Modic changes (MC). METHODS: A cross-sectional sub-analyses of a prospective cohort was performed. Fasting blood samples were collected from patients with and without lumbar MC who had undergone spinal fusion or microdiscectomy. An 80-plex panel and CCL5/RANTES were used to assess preoperative plasma cytokine concentrations. Patient demographics and imaging phenotypes were also assessed. RESULTS: Thirty-one subjects were analysed (n = 18 no MC; n = 13 MC). No significant differences were found in age, sex, body mass index, smoking and alcohol history, and surgical procedure (i.e. fusion, decompression) between the two groups (p > 0.05). Several statistically significant blood biomarkers in MC patients were identified, including elevated levels of C-C Motif Chemokine Ligand 5 (CCL5, p = 0.0006), while Macrophage Migration Inhibitory Factor (MIF) was significantly lower (p = 0.009). Additionally, C-X-C Motif Chemokine Ligand 5 (CXCL5, p = 0.052), Pentraxin 3 (PTX3, p = 0.06) and Galectin-3 (Gal-3, p = 0.07) showed potential relevance. Moreover, MC patients exhibited significantly higher levels of disc degeneration (p = 0.0001) and displacement severity (p = 0.020). Based on multivariate analyses and controlling for disc degeneration/displacement, CCL5 (OR 1.02; 95% CI 1.002-1.033; p = 0.028) and MIF (OR 0.60; 95% CI 0.382-0.951; p = 0.030) were independently associated with MC patients. CONCLUSION: This "proof-of-concept" study is the first to identify specific and significantly circulating blood biomarkers associated with symptomatic patients with lumbar MC, independent of disc alterations of degeneration and/or bulges/herniations. Specifically, differences in CCL5 and MIF protein levels were significantly noted in MC patients compared to those without MC.


Asunto(s)
Degeneración del Disco Intervertebral , Desplazamiento del Disco Intervertebral , Humanos , Desplazamiento del Disco Intervertebral/cirugía , Estudios Prospectivos , Estudios Transversales , Ligandos , Vértebras Lumbares/cirugía , Biomarcadores , Imagen por Resonancia Magnética , Quimiocinas
3.
Orthop J Sports Med ; 12(2): 23259671231169200, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38361996

RESUMEN

Background: Alterations in hip kinematics during functional tasks occur in positions that cause anterior impingement in patients with femoroacetabular impingement (FAI) syndrome. However, tasks that do not promote motions of symptomatic hip impingement remain understudied. Purpose: To compare movement patterns of the hip and pelvis during a step-down pivot-turn task between patients with FAI and controls as well as in patients with FAI before and after hip arthroscopy. Study Design: Controlled laboratory study. Methods: Three-dimensional motion capture was acquired in 32 patients with FAI and 27 controls during a step-down pivot-turn task. An FAI subsample (n = 14) completed testing 9.2 ± 2.0 months (mean ± SD; range, 5.8-13.1 months) after hip arthroscopy. Statistical parametric mapping analysis was used to analyze hip and pelvis time series waveforms (1) between the FAI and control groups, (2) in the FAI group before versus after hip arthroscopy, and (3) in the FAI group after hip arthroscopy versus the control group. Continuous parametric variables were analyzed by paired t test and nonparametric variables by chi-square test. Results: There were no significant differences in demographics between the FAI and control groups. Before hip arthroscopy, patients with FAI demonstrated reduced hip flexion (P = .041) and external rotation (P = .027), as well as decreased anterior pelvic tilt (P = .049) and forward rotation (P = .043), when compared with controls. After hip arthroscopy, patients demonstrated greater hip flexion (P < .001) and external rotation of the operative hip (P < .001), in addition to increased anterior pelvic tilt (P≤ .036) and pelvic rise (P≤ .049), as compared with preoperative values. Postoperatively, the FAI group demonstrated greater hip flexion (P≤ .047) and lower forward pelvic rotation (P = .003) as compared with the control group. Conclusion: Movement pattern differences between the FAI and control groups during the nonimpingement-related step-down pivot-turn task were characterized by differences in the sagittal and transverse planes of the hip and pelvis. After hip arthroscopy, patients exhibited greater hip flexion and external rotation and increased pelvic anterior tilt and pelvic rise as compared with presurgery. When compared with controls, patients with FAI demonstrated greater hip flexion and lower pelvic forward rotation postoperatively. Clinical Relevance: These findings indicate that hip and pelvis biomechanics are altered even during tasks that do not reproduce the anterior impingement position.

4.
J Shoulder Elbow Surg ; 33(2): 223-233, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37774830

RESUMEN

BACKGROUND: Traditional, commercially sourced patient-specific instrumentation (PSI) systems for shoulder arthroplasty improve glenoid component placement but can involve considerable cost and outsourcing delays. The purpose of this randomized controlled trial was to compare the accuracy of glenoid component positioning in anatomic total shoulder arthroplasty (aTSA) using an in-house, point-of-care, 3-dimensionally (3D) printed patient-specific glenoid drill guide vs. standard nonspecific instrumentation. METHODS: This single-center randomized controlled trial included 36 adult patients undergoing primary aTSA. Patients were blinded and randomized 1:1 to either the PSI or the standard aTSA guide groups. The primary endpoint was the accuracy of glenoid component placement (version and inclination), which was determined using a metal-suppression computed tomography scan taken between 6 weeks and 1 year postoperatively. Deviation from the preoperative 3D templating plan was calculated for each patient. Blinded postoperative computed tomography measurements were performed by a fellowship-trained shoulder surgeon and a musculoskeletal radiologist. RESULTS: Nineteen patients were randomized to the patient-specific glenoid drill guide group, and 17 patients were allocated to the standard instrumentation control group. There were no significant differences between the 2 groups for native version (P = .527) or inclination (P = .415). The version correction was similar between the 2 groups (P = .551), and the PSI group was significantly more accurate when correcting version than the control group (P = .042). The PSI group required a significantly greater inclination correction than the control group (P = .002); however, the 2 groups still had similar accuracy when correcting inclination (P = .851). For the PSI group, there was no correlation between the accuracy of component placement and native version, native inclination, or the Walch classification of glenoid wear (P > .05). For the control group, accuracy when correcting version was inversely correlated with native version (P = .033), but accuracy was not correlated with native inclination or the Walch classification of glenoid wear (P > .05). The intraclass correlation coefficient was 0.703 and 0.848 when measuring version and inclination accuracy, respectively. CONCLUSION: When compared with standard instrumentation, the use of in-house, 3D printed, patient-specific glenoid drill guides during aTSA led to more accurate glenoid component version correction and similarly accurate inclination correction. Additional research should examine the influence of proper component position and use of PSI on clinical outcomes.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Escápula/cirugía , Artroplastia , Tomografía Computarizada por Rayos X , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Imagenología Tridimensional/métodos
5.
Knee ; 41: 214-220, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36724580

RESUMEN

PURPOSE: Few studies exist regarding sagittal alignment describing femur morphology in navigation-aided surgery. This study investigated the three-dimensional (3D) sagittal femoral alignment of the whole femur. METHODS: Seventy-three consecutive patients (59 females, 14 males, mean age: 76.1 years), yielding 140 femurs, were included in this study. A computed-tomography-based patient-specific 3D femur model was used to define a mechanical axis-based reference plane. Proximal and distal femoral axis angles (PFA, DFA) to the reference plane were measured in 3D using custom software. PFA and DFA represent the proximal and distal inclination of the femoral anatomical axis in sagittal plane, respectively. RESULTS: PFA (10.6 ± 1.5°) was greater than DFA (2.6 ± 1.6°; P < 0.0001). DFA in females (2.3 ± 1.4°) was smaller than in males (3.9 ± 1.7°; P < 0.0001). CONCLUSION: This is the first report of measurement of femoral sagittal alignment related to both 3D anatomy and decision making of femoral flexion angle using navigation surgery for total knee arthroplasty. This report shows a robust DFA measurement that could be used as a template for femoral implants flexion angle when performing both conventional and navigated total knee arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Pueblos del Este de Asia , Fémur , Osteoartritis de la Rodilla , Cirugía Asistida por Computador , Anciano , Femenino , Humanos , Masculino , Artroplastia de Reemplazo de Rodilla/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Fémur/anatomía & histología , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Extremidad Inferior , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/etnología , Osteoartritis de la Rodilla/cirugía , Tomografía Computarizada por Rayos X , Imagenología Tridimensional , Cirugía Asistida por Computador/métodos
6.
J Craniofac Surg ; 34(1): e96-e98, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36608091

RESUMEN

Infantile cranial development typically occurs in a predictable sequence of events; however, less is known about how the development occurs in isolated, nonsyndromic congenital craniofacial anomalies. Furthermore, the timing of pediatric cranioplasty has been extrapolated from adult studies. Thus, the management of nonsyndromic congenital craniofacial anomalies presents with unique challenges to the craniofacial surgeon. The authors describe the case of a baby girl who was born with right Tessier 3 cleft, cleft palate, anophthalmos, and severe left craniofacial microsomia with Pruzansky grade III left mandibular anomaly. By analyzing 3-dimensional chronological models of the patient, the authors found that her abnormal fontanelle initially increased in size until 22 weeks of age, with subsequent spontaneous closure at a rate of 60.53 mm2/y. Although similar cranial anomalies are typically surgically corrected early in life, delaying treatment until after 2 years of age may be appropriate in some patients, obviating surgical morbidity in the newborn period.


Asunto(s)
Anoftalmos , Fisura del Paladar , Síndrome de Goldenhar , Femenino , Humanos , Lactante , Fisura del Paladar/cirugía , Huesos Faciales/anomalías , Cráneo
7.
J Orthop Res ; 41(6): 1256-1265, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36227086

RESUMEN

There are considerable limitations associated with the standard 2D imaging currently used for the diagnosis and surgical planning of cam-type femoroacetabular impingement syndrome (FAIS). The aim of this study was to determine the accuracy of a new patient-specific shape-fitting method that quantifies cam morphology in 3D based solely on preoperative MRI imaging. Preoperative and postoperative 1.5T MRI scans were performed on n = 15 patients to generate 3D models of the proximal femur, in turn used to create the actual and the virtual cam. The actual cams were reconstructed by subtracting the postoperative from the preoperative 3D model and used as reference, while the virtual cams were generated by subtracting the preoperative 3D model from the virtual shape template produced with the shape-fitting method based solely on preoperative MRI scans. The accuracy of the shape-fitting method was tested on all patients by evaluating the agreement between the metrics of height, surface area, and volume that quantified virtual and actual cams. Accuracy of the shape-fitting method was demonstrated obtaining a 97.8% average level of agreement between these metrics. In conclusion, the shape-fitting technique is a noninvasive and patient-specific tool for the quantification and localization of cam morphology. Future studies will include the implementation of the technique within a clinically based software for diagnosis and surgical planning for cam-type FAIS.


Asunto(s)
Pinzamiento Femoroacetabular , Humanos , Pinzamiento Femoroacetabular/diagnóstico por imagen , Pinzamiento Femoroacetabular/cirugía , Imagenología Tridimensional/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía
8.
Global Spine J ; 13(7): 1803-1811, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34736350

RESUMEN

STUDY DESIGN: Basic Science. OBJECTIVE: Poor subchondral bone mineral density (sBMD) has been linked with subsidence of cervical interbody devices or grafts, which are traditionally placed centrally on the endplates. Considering that sBMD reflects long-term stress distributions, we hypothesize that the cervical uncovertebral joints are denser than the central endplate region. This study sought to investigate density distributions using computed tomography osteoabsorptiometry (CT-OAM). METHODS: Twelve human cervical spines from C3-C7 (60 vertebrae, 120 endplates) were imaged with CT and segmented to create 3D reconstructions. The superior and inferior endplates were isolated, and the sBMD of the whole endplate, endplate center, and uncus was evaluated using CT-OAM. Density distributions were compared across the subaxial cervical spine. RESULTS: The uncinate region of the inferior and superior endplates was significantly denser than the central endplate across all vertebral levels (P < .01). When comparing sBMD of the whole inferior and superior endplates, the superior endplate was significantly denser than the inferior endplate (P < .0001). However, the inferior uncus was denser than the superior uncus (P = .035). When assessing sBMD by vertebral level, peak densities were observed at C4 and C5, while C7 was, on average, significantly less dense than all other vertebrae. CONCLUSION: The subchondral bone of the cervical uncovertebral joints is significantly denser than the central endplates. While the superior endplate in its entirety is denser than the inferior endplate, the inverse was true for the uncovertebral joints. This study serves as a basis for future investigations of new implant designs and their implications on subsidence.

9.
Sci Rep ; 12(1): 3231, 2022 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-35217693

RESUMEN

The purpose of this study is to evaluate the glenohumeral contact area, center of glenohumeral contact area, and center of humeral head during simulated pitching motion in collegiate baseball pitchers using four-dimensional computed tomography (4D CT). We obtained 4D CT data from the dominant and non-dominant shoulders of eight collegiate baseball pitchers during the cocking motion. CT image data of each joint were reconstructed using a 3D reconstruction software package. The glenohumeral contact area, center of glenohumeral contact area, center of humeral head, and oblateness of humeral head were calculated from 3D bone models using customized software. The center of glenohumeral contact area translated from anterior to posterior during maximum external rotation to maximum internal rotation (0.58 ± 0.63 mm on the dominant side and 0.99 ± 0.82 mm on the non-dominant side). The center of humeral head translated from posterior to anterior during maximum external rotation to maximum internal rotation (0.76 ± 0.75 mm on the dominant side and 1.21 ± 0.78 mm on the non-dominant side). The increase in anterior translation of the center of glenohumeral contact area was associated with the increase in posterior translation of the center of humeral head. Also, the increase in translation of the center of humeral head and glenohumeral contact area were associated with the increase in oblateness of the humeral head. 4D CT analyses demonstrated that the center of humeral head translated in the opposite direction to that of the center of glenohumeral contact area during external rotation to internal rotation in abduction in the dominant and non-dominant shoulders. The oblateness of the humeral head may cause this diametric translation. 4D CT scanning and the software for bone surface modeling of the glenohumeral joint enabled quantitative assessment of glenohumeral micromotion and be used for kinematic evaluation of throwing athletes.


Asunto(s)
Béisbol , Articulación del Hombro , Fenómenos Biomecánicos , Tomografía Computarizada Cuatridimensional , Humanos , Rango del Movimiento Articular , Rotación , Articulación del Hombro/diagnóstico por imagen
10.
Eur Spine J ; 31(5): 1069-1079, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35129673

RESUMEN

PURPOSE: It's a long-held belief that Modic changes (MC) occur only in adults, with advanced age, and are highly associated with pain and adverse outcomes. The following study addressed the epidemiology, risk factors and clinical relevance of MC in young paediatric patients. METHODS: Two hundred and seven consecutive patients with no history of deformities, neoplasms, trauma, or infections were included in this ambispective study. MRIs were utilized to assess MCs and types, and other degenerative disc/endplate abnormalities. Subject demographics, duration of symptoms, clinic visits, conservative management (physical therapy, NSAIDs, opioids, injections) and surgery were noted. RESULTS: The mean age was 16.5 years old (46.9% males), 14% had MCs and they occurred throughout the spine. Subject baseline demographics were similar between MCs and non-MCs patients (p > 0.05). Modic type 2 (50%) was the most common type (type 1:27.1%; type 3:18.8%; mixed:4.7%). Multivariate analyses noted that endplate damage (OR: 11.36), disc degeneration (OR: 5.81), disc space narrowing (OR: 5.77), Schmorl's nodes (OR: 4.30) and spondylolisthesis (OR: 3.55) to be significantly associated with MCs (p < 0.05). No significant differences in conservative management were noted between Modic and non-MCs patients (p > 0.05). Among surgery patients (n = 44), 21% also had MCs (p = 0.134). Symptom-duration was significantly greater in MC patients (p = 0.049). CONCLUSION: Contrary to traditional dogma, robust evidence now exists noting that MCs and their types can develop in children. Our findings give credence to the "Juvenile" variant of MCs, whereby its implications throughout the lifespan need to be assessed. Juvenile MCs have prolonged symptoms and related to specific structural spine phenotypes.


Asunto(s)
Distinciones y Premios , Degeneración del Disco Intervertebral , Desplazamiento del Disco Intervertebral , Dolor de la Región Lumbar , Niño , Femenino , Humanos , Degeneración del Disco Intervertebral/epidemiología , Desplazamiento del Disco Intervertebral/complicaciones , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/epidemiología , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/efectos adversos , Masculino , Factores de Riesgo
11.
Eur Spine J ; 31(8): 2007-2021, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35084588

RESUMEN

BACKGROUND: As big data and artificial intelligence (AI) in spine care, and medicine as a whole, continue to be at the forefront of research, careful consideration to the quality and techniques utilized is necessary. Predictive modeling, data science, and deep analytics have taken center stage. Within that space, AI and machine learning (ML) approaches toward the use of spine imaging have gathered considerable attention in the past decade. Although several benefits of such applications exist, limitations are also present and need to be considered. PURPOSE: The following narrative review presents the current status of AI, in particular, ML, with special regard to imaging studies, in the field of spinal research. METHODS: A multi-database assessment of the literature was conducted up to September 1, 2021, that addressed AI as it related to imaging of the spine. Articles written in English were selected and critically assessed. RESULTS: Overall, the review discussed the limitations, data quality and applications of ML models in the context of spine imaging. In particular, we addressed the data quality and ML algorithms in spine imaging research by describing preliminary results from a widely accessible imaging algorithm that is currently available for spine specialists to reference for information on severity of spine disease and degeneration which ultimately may alter clinical decision-making. In addition, awareness of the current, under-recognized regulation surrounding the execution of ML for spine imaging was raised. CONCLUSIONS: Recommendations were provided for conducting high-quality, standardized AI applications for spine imaging.


Asunto(s)
Inteligencia Artificial , Enfermedades de la Columna Vertebral , Algoritmos , Humanos , Aprendizaje Automático , Enfermedades de la Columna Vertebral/diagnóstico por imagen
12.
J Orthop Res ; 40(5): 1174-1181, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34192370

RESUMEN

The purpose of this in vitro study was to quantify the bone resected from the proximal femur during hip arthroscopy using metrics generated from magnetic resonance imaging (MRI) and computed tomography (CT) reconstructed three-dimensional (3D) bone models. Seven cadaveric hemi-pelvises underwent both a 1.5 T MRI and CT scan before and following an arthroscopic proximal femoral osteochondroplasty. The images from MRI and CT were segmented to generate 3D proximal femoral surface models. A validated 3D--3D registration method was used to compare surface--to--surface distances between the 3D models before and following surgery. The new metrics of maximum height, mean height, surface area and volume, were computed to quantify bone resected during osteochondroplasty. Stability of the metrics across imaging modalities was established through paired sample t--tests and bivariate correlation. Bivariate correlation analyses indicated strong correlations between all metrics (r = 0.728--0.878) computed from MRI and CT derived models. There were no differences in the MRI- and CT-based metrics used to quantify bone resected during femoral osteochondroplasty. Preoperative- and postoperative MRI and CT derived 3D bone models can be used to quantify bone resected during femoral osteochondroplasty, without significant differences between the imaging modalities.


Asunto(s)
Pinzamiento Femoroacetabular , Artroscopía/métodos , Benchmarking , Pinzamiento Femoroacetabular/diagnóstico por imagen , Pinzamiento Femoroacetabular/cirugía , Articulación de la Cadera/cirugía , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos
13.
PLoS One ; 16(10): e0259001, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34705863

RESUMEN

The vertebral endplate forms a structural boundary between intervertebral disc and the trabecular bone of the vertebral body. As a mechanical interface between the stiff bone and resilient disc, the endplate is the weakest portion of the vertebral-disc complex and is predisposed to mechanical failure. However, the literature concerning the bone mineral density (BMD) distribution within the spinal endplate is comparatively sparse. The objective of this study is to investigate the three-dimensional (3D) distribution of computed tomography (CT) attenuation across the lumbosacral endplate measured in Hounsfield Units (HU). A total of 308 endplates from 28 cadaveric fresh-frozen lumbosacral spines were used in this study. Each spine was CT-scanned and the resulting DICOM data was used to obtain HU values of the bone endplate. Each individual endplate surface was subdivided into five clinically-relevant topographic zones. Attenuation was analyzed by spinal levels, sites (superior or inferior endplate) and endplate region. The highest HU values were found at the S1 endplate. Comparisons between the superior and inferior endplates showed the HU values in inferior endplates were significantly higher than those in the superior endplates within the same vertebra and the HU values in endplates cranial to the disc were significantly higher than those in the endplates caudal to the disc within the same disc. Attenuation in the peripheral region was significantly higher than in the central region by 32.5%. Regional comparison within the peripheral region showed the HU values in the posterior region were significantly higher than those in the anterior region and the HU values in the left region were significantly higher than those in the right region. This study provided detailed data on the regional HU distribution across the lumbosacral endplate, which can be useful to understand causes of some endplate lesions, such as fracture, and also to design interbody instrumentation.


Asunto(s)
Disco Intervertebral/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Región Lumbosacra/patología , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
14.
Am J Sports Med ; 49(11): 2984-2993, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34339327

RESUMEN

BACKGROUND: Impairments in squat depth have been reported in patients with femoroacetabular impingement syndrome (FAIS). However, little is known about single-leg squat (SLS) performance in these patients, despite this task being commonly used in the rehabilitation and training settings. PURPOSE/HYPOTHESIS: The aims of this study were (1) to investigate whether patients with FAIS demonstrate differences in SLS performance compared with healthy controls and (2) to determine whether dynamic range of motion (ROM), muscle strength, hip morphologic measures, hip pain, and hip-specific function predict SLS performance in patients with FAIS. We hypothesized that patients with FAIS would demonstrate impaired SLS performance and that impaired hip biomechanics, muscle strength, and hip-specific function would predict squat performance in patients with FAIS. STUDY DESIGN: Controlled laboratory study. METHODS: Three-dimensional (3D) kinematic data were collected at 100 Hz using a 20-camera 3D motion capture system during 3 SLS trials in 34 patients with FAIS and 26 healthy controls. Isometric muscle strength was tested with a stationary handheld dynamometer in all participants. Squat performance was quantified by squat depth (in meters), and the biomechanical variables of dynamic ROM of the pelvis, the hip, the knee, and the ankle in all planes were calculated. In patients with FAIS, femoral and acetabular morphology were measured using radiographic alpha angles and lateral center-edge angles. Hip pain and hip-specific function were measured using the visual analog scale for pain and the Hip Outcome Score Activities of Daily Living subscale, respectively. Two-tailed independent-samples t tests were used to determine between-group differences for squat depth, dynamic ROM variables, and muscle strength. A hierarchical multiple linear regression (MLR) model was used to determine whether biomechanical variables, muscle strength, hip morphology measures, hip pain, and hip-specific function were predictors of squat depth. All statistical analyses were performed using SPSS Version 26. RESULTS: There were no between-group differences in age (FAIS, 30.0 ± 7.0 years vs controls, 27.3 ± 7.0 years; P = .18) or body mass index (FAIS, 23.1 ± 2.8 vs controls, 22.6 ± 3.2; P = .51). Squat depth was less in patients with FAIS compared with healthy controls (FAIS, 0.24 ± 0.4 m vs controls, 0.29 ± 0.05 m; P < .001). In the sagittal plane, patients with FAIS demonstrated less dynamic ROM of the hip (FAIS, 67.8°± 12.4° vs controls, 79.2°± 12.5°; P = .001) and the knee (FAIS, 71.9°± 9.4° vs controls, 78.9°± 13.2°; P = .02) compared with controls. Patients with FAIS also demonstrated a less dynamic coronal plane pelvis ROM (FAIS, 11.3°± 5.0° vs controls, 14.4°± 6.7°; P = .044). Patients with FAIS had reduced hip muscle strength of the hip external rotator (FAIS, 1 ± 0.3 N/kg vs controls, 1.2 ± 0.3 N/kg; P = .034), hip internal rotator (FAIS, 0.8 ± 0.3 N/kg vs controls 1 ± 0.3 N/kg; P = .03), and hip flexor (FAIS, 4 ± 1.1 N/kg vs controls, 4.8 ± 1.2 N/kg; P = .013) muscle groups. The hierarchical MLR revealed that the dynamic ROM of the hip, the knee, and the pelvis, the hip external rotation muscle strength, and the femoral alpha angles were all significant predictors of squat performance, and the final MLR model explained 92.4% of the total variance in squat depth in patients with FAIS. CONCLUSION: Patients with FAIS demonstrate impaired SLS squat performance compared with healthy controls. This impaired squat performance is predominantly predicted by sagittal plane knee and hip biomechanics and hip external rotator strength, and less by frontal plane pelvic ROM and hip morphology in patients with FAIS. CLINICAL RELEVANCE: Clinicians should focus treatment on improving dynamic ROM and hip external rotator muscle strength to improve squat performance; however, femoral morphology should also be considered in the treatment paradigm.


Asunto(s)
Pinzamiento Femoroacetabular , Pierna , Actividades Cotidianas , Adulto , Fenómenos Biomecánicos , Pinzamiento Femoroacetabular/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Humanos , Debilidad Muscular , Rango del Movimiento Articular , Rotación , Adulto Joven
15.
PLoS One ; 16(7): e0253019, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34237065

RESUMEN

BACKGROUND: Although the pedicle is routinely used as a surgical fixation site, the pedicle wall bone area fraction (bone area per unit area) and its distribution at the isthmus of the pedicle remain unknown. The bone area fraction at the pedicle isthmus is an important factor contributing to the strength of pedicle screw constructs. This study investigates the lumbar pedicle wall microstructure based on micro-computed tomography. METHODS: Six fresh-frozen cadaveric lumbar spines were analyzed. Left and right pedicles of each vertebra from L1 to L5 were resected for micro-computed tomography scanning. Data was analyzed with custom-written software to determine regional variation in pedicle wall bone area fraction. The pedicular cross-section was divided into four regions: lateral, medial, cranial, and caudal. The mean bone area fraction values for each region were calculated for all lumbar spine levels. RESULTS: The lateral region showed lower bone area fraction than the medial region at all spinal levels. Bone area fraction in the medial region was the highest at all levels except for L4, and the median values were 99.8% (95.9-100%). There were significant differences between the lateral region and the caudal region at L1, L2 and L3, but none at L4 and L5. The bone area fraction in the lateral region was less than 64% at all spinal levels and that in the caudal region was less than 67% at the L4 and L5 levels. CONCLUSIONS: This study provides initial detailed data on the lumbar pedicle wall microstructure based on micro-computed tomography. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral and caudal walls.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Anciano , Femenino , Humanos , Vértebras Lumbares/anatomía & histología , Vértebras Lumbares/ultraestructura , Masculino , Persona de Mediana Edad , Microtomografía por Rayos X/métodos
16.
Sci Rep ; 11(1): 1709, 2021 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-33462307

RESUMEN

This study investigated in vivo the three-dimensional distribution of CT attenuation in the lumbar spine pedicle wall measured in Hounsfield Unit (HU). Seventy-five volunteers underwent clinical lumbar spine CT scans. Data was analyzed with custom-written software to determine the regional variation in pedicle wall attenuation values. A cylindrical coordinate system oriented along the pedicle's long axis was used to calculate the pedicular wall attenuation distribution three-dimensionally and the highest attenuation value was identified. The pedicular cross-section was divided into four quadrants: lateral, medial, cranial, and caudal. The mean HU value for each quadrant was calculated for all lumbar spine levels (L1-5). The pedicle wall attenuation was analyzed by gender, age, spinal levels and anatomical quadrant. The mean HU values of the pedicle wall at L1 and L5 were significantly lower than the values between L2-4 in both genders and in both age groups. Furthermore, the medial quadrant showed higher HU values than the lateral quadrant at all levels and the caudal quadrant showed higher HU values at L1-3 and lower HU values at L4-5 than the cranial quadrant. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral wall.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Vértebras Lumbares/fisiología , Masculino , Persona de Mediana Edad , Cuerpo Vertebral/diagnóstico por imagen , Cuerpo Vertebral/fisiología , Adulto Joven
17.
J Orthop Res ; 39(8): 1732-1744, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32816312

RESUMEN

Early onset adjacent segment degeneration (ASD) can be found within six months after anterior cervical discectomy and fusion (ACDF). Deficits in deep paraspinal neck muscles may be related to early onset ASD. This study aimed to determine whether the morphometry of preoperative deep neck muscles (multifidus and semispinalis cervicis) predicted early onset ASD in patients with ACDF. Thirty-two cases of early onset ASD after a two-level ACDF and 30 matched non-ASD cases were identified from a large-scale cohort. The preoperative total cross-sectional area (CSA) of bilateral deep neck muscles and the lean muscle CSAs from C3 to C7 levels were measured manually on T2-weighted magnetic resonance imaging. Paraspinal muscle CSA asymmetry at each level was calculated. A support vector machine (SVM) algorithm was used to identify demographic, radiographic, and/or muscle parameters that predicted proximal/distal ASD development. No significant between-group differences in demographic or preoperative radiographic data were noted (mean age: 52.4 ± 10.9 years). ACDFs comprised C3 to C5 (n = 9), C4 to C6 (n = 20), and C5 to C7 (n = 32) cases. Eighteen, eight, and six patients had proximal, distal, or both ASD, respectively. The SVM model achieved high accuracy (96.7%) and an area under the curve (AUC = 0.97) for predicting early onset ASD. Asymmetry of fat at C5 (coefficient: 0.06), and standardized measures of C7 lean (coefficient: 0.05) and total CSA measures (coefficient: 0.05) were the strongest predictors of early onset ASD. This is the first study to show that preoperative deep neck muscle CSA, composition, and asymmetry at C5 to C7 independently predicted postoperative early onset ASD in patients with ACDF. Paraspinal muscle assessments are recommended to identify high-risk patients for personalized intervention.


Asunto(s)
Degeneración del Disco Intervertebral , Fusión Vertebral , Adulto , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/patología , Vértebras Cervicales/cirugía , Humanos , Degeneración del Disco Intervertebral/etiología , Aprendizaje Automático , Persona de Mediana Edad , Músculos del Cuello/patología , Músculos Paraespinales/diagnóstico por imagen , Músculos Paraespinales/patología , Estudios Retrospectivos , Fusión Vertebral/métodos
19.
Arthroscopy ; 36(10): 2623-2632, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32534004

RESUMEN

PURPOSE: (1) To compare the acetabular coverage between dysplasia, borderline dysplasia, and control acetabulum in a quantitative 3-dimensional manner; and (2) to evaluate correlations between the radiologic parameters and the 3-dimensional zonal-acetabular coverage. METHODS: We reviewed contralateral hip computed tomography images of patients 16 to 60 years of age who underwent 1 of 3 types of surgeries: eccentric rotational acetabular osteotomy, curved intertrochanteric varus osteotomy, and total hip replacement with minimum 1-year follow-up from January 2013 to April 2018. A point-cloud model of the acetabulum created from computed tomography was divided into 6 zones. Three-dimensional acetabular coverage was measured radially at intervals of 1°. Mean radial acetabular coverage for each zone was named ZAC (zonal acetabular coverage) and was compared among the 3 subgroups (control: 25° ≤lateral center-edge angle [LCEA] <40°; borderline: 20° ≤LCEA <25°; and dysplasia: LCEA ≤20°) statistically. Further, the correlations between the ZAC in each zone and the LCEA were analyzed using Pearson's correlation coefficient. RESULTS: One-hundred fifteen hips were categorized as control (36 hips), borderline (32 hips), and dysplasia (47 hips). The mean anterocranial ZAC in the borderline (87.5 ± 5.7°) was smaller than that in the control (92.6 ± 5.9°, P = .005) but did not differ compared with the dysplasia (84.5 ± 7.6°, P = .131). In contrast, the anterocaudal (71.2 ± 5.0°), posterocranial (85.0 ± 6.4°), and posterocaudal (82.4 ± 4.5°) mean ZACs in the borderline were not different from those in the control (anterocaudal, 74.3 ± 4.6°, P = .090; posterocranial, 87.9 ± 4.3°, P = .082; posterocaudal, 85.1 ± 5.0°, P = .069) respectively. Although there was a very strong positive correlation with supra-anterior ZAC and LCEA (r = 0.750, P < .001), the correlation between the anterocranial ZAC and LCEA was relatively weak (r = 0.574, P < .001). CONCLUSIONS: The anterosuperior acetabular coverage in the borderline dysplastic acetabulum is more similar to the dysplastic acetabulum than to the normal acetabulum. CLINICAL RELEVANCE: This study emphasizes the importance of evaluating not only the lateral but also the anterior coverage in borderline dysplasia.


Asunto(s)
Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/cirugía , Adolescente , Adulto , Femenino , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/cirugía , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Osteotomía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
20.
Arthrosc Sports Med Rehabil ; 2(2): e91-e95, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32368744

RESUMEN

PURPOSE: To determine whether statistical shape modeling can detect subtle morphologic differences in the shape of the proximal femur that correlate with clinical findings of unilateral femoroacetabular impingement syndrome. METHODS: Patients who had diagnoses of unilateral femoroacetabular impingement syndrome and who had existing computed tomography scans of their pelvises were included. Three-dimensional shape models in the form of triangle meshes were generated from the computed tomography images. Statistical shapes of cam-type and normal hips were compared to identify structural differences. RESULTS: The study included 33 hips in 17 subjects. Of the subjects, 7 (41.1%) were male, and 10 (58.9%) were female. The subjects ranged in age from 17-60 years of age (mean 36.3 ± 11.0 years old). The statistical shape modeling found mean shapes and modes after optimizing the groupwise correspondence. Symptomatic hips demonstrated 1 mm of thickening as compared to the femoral necks of asymptomatic hips, corresponding to cam lesions. CONCLUSIONS: Symptomatic cam deformities were an average of 1 mm more prominent in the femoral neck region as compared to the asymptomatic hips when using statistical shape modeling. The present study provides a proof of the concept that statistical shape modeling can be used to examine and help define cam morphology and that subtle morphologic differences may account for developing femoroacetabular impingement syndrome. CLINICAL RELEVANCE: Using the methods presented in this study, it would be possible to define cam and pincer morphologies by creating statistical shape models, and this work could potentially lead to the development of a new classification system for femoroacetabular impingement syndrome lesions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...